9400 HighLine | Parameter setting & configuration

Standard TAs

TA "Actuator – speed" | Application error messages

264

Firmware 1.37 - 09/2006

L

11.2.12

Application error messages

For the output of application-specific error messages an FB instance ApplicationError of the

function block L_DevApplErr is available in the network.

r

Via the 8 boolean inputs up to 8 different application error messages with

parameterisable module ID, error ID and error response can be released by the

application.

r

Parameter setting: Tab All parameters

Reset of error message
In the Lenze setting the digital input DI5 for resetting (acknowledging) an error message is

connected to the input DI_bResetError1 of the drive interface.

Error message

Error-ID

Error response

1

Speed follower in limitation

8001

Warning locked

2

- 8000

Error

3

- 8000

Error

4

- 8000

Error

5

- 8000

Error

6

- 8000

Error

7

- 8000

Error

8

- 8000

Error

Parameters

Lenze setting

C05900

Module-ID

980

C05901/1...8

Error ID 1 ... 8

See table above

C05902/1...8

Error response 1 ... 8

See table above