15 application error messages, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 327

Advertising
background image

L

Firmware 1.37 - 09/2006

327

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Electronic gearbox" | Application error messages

12.2.15

Application error messages

For the output of application-specific error messages an FB instance ApplicationError of the

function block L_DevApplErr is available in the network.

r

Via the 8 boolean inputs up to 8 different application error messages with

parameterisable module ID, error ID and error response can be released by the

application.

r

The first four inputs can be connected to the multiplexer parameters with the desired

tripping signals. The next four inputs are firmly connected to the tripping signals of the

application.

r

Parameter setting: Tab All parameters

Error message

Error-ID

Error response

1

Free (configurable via C03060/1)

8001

No reaction

2

Free (configurable via C03060/2)

8002

Error

3

Free (configurable via C03060/3)

8003

Error

4

Free (configurable via C03060/4)

8004

Error

5

Following error

8005

Warning

6

Drive cannot follow

8006

Warning

7

Drive system interrupted

8007

Quick stop by trouble

8

External fault in drive system

8008

Quick stop by trouble

Parameters

Lenze setting

C03990

Module-ID

999

C03991/1...8

Error ID 1 ... 8

See table above

C03992/1...8

Error response 1 ... 8

See table above

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE  Application fault 1

C03060/1

FALSE  Application fault 2

C03060/2

FALSE  Application fault 3

C03060/3

FALSE  Application fault 4

C03060/4

Advertising