9400 HighLine | Parameter setting & configuration

Drive interface

Controller commands

52

Firmware 1.37 - 09/2006

L

4.6

Controller commands

Different controller commands are available for project management within the

controller. They can be activated under code

C00002

.

r

The following subsections describe the most important controller commands for

project management and parameter set management in the controller.

r

With an online connection, the controller commands can be activated from the

»Engineer« by selecting the corresponding command in the Parameters tab under

C00002

. As an alternative, the controller commands can be activated via the keypad.

r

In

C00003

the number and the status of the device command executed last is

indicated.

Status display for device command

(C 54)

O

Tip!
Many frequently required controller commands (e.g. "Save start parameters") can

be executed via the toolbar icons of the »Engineers«.

Note!

Before the supply voltage is switched off after a device command has been

transmitted via

C00002

, it must be checked via

C00003

if the device command

has been completed successfully!
• The "0x00" status in the lower 16 bits of

C00003

means that the device

command has been executed successfully.

Note!

Controller commands that can be executed via the toolbar of the »Engineers«

always affect the element currently selected in the Project view including all

subelements.
• If no controller, but a system module is selected in the Project view, the

corresponding controller command will be activated in all lower-level

controllers having an online connection with the »Engineer«.

For the commands described in the following subsections, the controller must

be selected in the Project view.