Read error - service register [0x00720000, External error [0x00750000, Controller is enabled [0x00750001 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 462: Controller has been initialised [0x00750002, Controller in sto state [0x00750003, Controller: pulse inhibit is active [0x00750005, 0x20750000, 9400 highline | parameter setting & configuration

Advertising
background image

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Error messages of the operating system

462

Firmware 1.37 - 09/2006

L

Read error - service register [0x00720000]

External error [0x00750000]

Controller is enabled [0x00750001]

Controller has been initialised [0x00750002]

Controller in STO state [0x00750003]

Controller: Pulse inhibit is active [0x00750005]

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

An error has occurred while reading or writing the service

register.

Mains switching

• Please contact Lenze, if the problem occurs again.

Response (Lenze setting printed in bold)

Setting:

C00581

(; Adjustable response)

;

None … System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

The drive interface has activated the error message

"External error".

• The input DI_bSetExternError of the system block

LS_DriveInterface has been set to TRUE.

• Check external device to be monitored.

• Check assignment of the input DI_bSetExternError in

the application.

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

The controller is enabled and has the "Operation" state. - (Information only)

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

The controller has left the "Initialisation active" state.

- (Information only)

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

The controller has received the "safe torque off" request

and is now in the "Safe Torque Off active" state.

- (Information only)

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

The pulse inhibit is active in the controller.