9400 HighLine | Parameter setting & configuration

I/O terminals

Analog outputs

120

Firmware 1.37 - 09/2006

L

7.3

Analog outputs

The controller has 2 analog outputs that can be used to output internal analog signals as

voltage signals, e.g. for analog indicator control or as setpoint for slave drives.

7.3.1

Terminal assignment/electrical data

Note!

Initialisation behaviour:
• After mains switching up to the start of the application the analog outputs

remain set to 0 V.

Exception handling:
• In case of a critical exception in the application (e.g. reset) the analog outputs

are set to 0 V.

Terminal

Use

Electrical data

X3/AO1

Voltage output 1

Level: -10 V ... +10 V

(max. 2 mA)

Resolution: 11 bits + sign

Normalisation: ±2

30

≡ ±10 V

Conversion rate: 1 kHz

X3/AO2

Voltage output 2

Level: -10 V ... +10 V

(max. 2 mA)

Resolution: 11 bits + sign

Normalisation: ±2

30

≡ ±10 V

Conversion rate: 1 kHz

X3/GA

Reference potential (analog ground)

GA

AO1

AO2