9 activate/archive parameter set, Activate/archive parameter set (c 59), 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 59

Advertising
background image

L

Firmware 1.37 - 09/2006

59

9400 HighLine | Parameter setting & configuration

Drive interface

Controller commands

4.6.9

Activate/archive parameter set

In addition to the current parameter set, it is possible to store up to four additional

parameter sets (PS 1 ... PS 4) for each project in the memory module.
Using the corresponding controller commands, you can archive the current parameter set

settings in parameter sets PS 1 ... PS 4 and reactivate them, if required.

r

This allows you to define different controller settings for an application, which can

easily be loaded by means of the corresponding controller command, if required.

Activate parameter set
The following figure shows the controller commands which activate a parameter set on

the memory module (MM):

Archive parameter set
The following figure shows the controller commands which archive the current parameter

set:

PS

C00002 = 1

MM

9400

RAM

C00002 = 201

C00002 = 202

C00002 = 203

C00002 = 204

PS 2

PS 1

PS 3

PS 4

PS

PS

PS

MM

9400

RAM

C00002 = 301

C00002 = 302

C00002 = 303

C00002 = 304

PS 2

PS 1

PS 3

PS 4

C00002 = 11