9400 HighLine | Parameter setting & configuration

Basic drive functions

Brake control | Parameter setting

218

Firmware 1.37 - 09/2006

L

Waiting time for status monitoring
Every time the brake status changes, the waiting time set in

C02591

is awaited after the

brake opening or brake closing time has elapsed, before the monitoring of the brake

module/status input BRK_bBrakeApplied (if activated via C02583) and the standstill

monitoring function are switched active again.

r

During the "Closing the brake" process, a mechanical contact must signal the status

"brake closed" after the waiting time has elapsed.

r

During the "Releasing the brake" process, a mechanical contact must signal the status

"brake released" after the waiting time has elapsed.

[9-14] Definition of the waiting time for status monitoring



Brake status (with bouncing or transient response)



Active status monitoring

n

C02589

: Brake closing time

o

C02590

: Brake opening time

p

C02591

: Waiting time - status monit.

r

The waiting time in

C02591

must be

set so that bouncing of a feedback

contact and the transient response of

the brake current monitoring will be

suppressed completely.

r

If there is no appropriate feedback

after the waiting time has expired, the

error output BRK_bError is set to TRUE

until the next control attempt.

t

Ž

t

t

0

1

Œ



Ž

t

t

Stopping/Standstill

BRK_bReleaseBrakeOut

Advertising