Parameter reference

Parameter list | C02649

C02649

C02650

C02651

C02652

C02653

C02656

Parameter | Name:

C02649 | Ref. torque limit

Data type: INTEGER_32

Index: 21926

d

= 55A6

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

200.00 10.00 %

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C02650 | Ref. blocking time

Data type: UNSIGNED_32

Index: 21925

d

= 55A5

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

120.000 1.000 s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 1000

Parameter | Name:

C02651 | Ref. touch probe configuration

Data type: UNSIGNED_32

Index: 21924

d

= 55A4

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

4294967295 16

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02652 | Home pos. after mains switching

Data type: UNSIGNED_32

Index: 21923

d

= 55A3

h

Basic function "

Homing

"

Selection list

(Lenze setting printed in bold)

0 Delete
1 Received

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02653 | Max. angle of after mains switch.

Data type: INTEGER_32

Index: 21922

d

= 55A2

h

Basic function "

Homing

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

°

1000000 180 °

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02656 | Current position

Data type: INTEGER_32

Index: 21919

d

= 559F

h

Basic function "

Homing

"

Display range

(min. value | unit | max. value)

-214748.3647

Unit

214748.3647

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000