9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00105

554

Firmware 1.37 - 09/2006

L

C00105

C00106

C00107

C00114

C00118

Parameter | Name:

C00105 | Quick stop decel. time

Data type: UNSIGNED_32

Index: 24470

d

= 5F96

h

Time between quick stop activation and standstill plus relative inaccuracy time (

C00106

).

"

Basic functionQuick stop

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

999.999 0.000 s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 1000

Parameter | Name:

C00106 | Quick stop S-ramp time

Data type: UNSIGNED_32

Index: 24469

d

= 5F95

h

S-ramp time in [%] referred to the deceleration time set under

C00105

.

"

Basic functionQuick stop

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 0.00 %

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00107 | Ref. quick stop decel. time

Data type: UNSIGNED_8

Index: 24468

d

= 5F94

h

Reference for the deceleration time set in

C00105

.

"

Basic functionQuick stop

"

Selection list

(Lenze setting printed in bold)

0 Reference = reference speed

(C00011)

1 Ref. = Current speed

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00114 | DIx terminal polarity

Data type: UNSIGNED_8

Index: 24461

d

= 5F8D

h

"0" = positive logic (HIGH level = TRUE, LOW level = FALSE)

"1" = negative logic (HIGH level = FALSE, LOW level = TRUE)
Setting range

(min. value | unit | max. value)

0

1

Subcodes

Lenze setting

Information

C00114/1

0

Terminal polarity of digital inputs 1 ... 8

C00114/...
C00114/8

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00118 | DOx terminal polarity

Data type: UNSIGNED_8

Index: 24457

d

= 5F89

h

"0" ≡ positive logic (TRUE ≡ HIGH level, FALSE ≡ LOW level)

"1" ≡ negative logic (FALSE ≡ HIGH level, TRUE ≡ LOW level)
Setting range

(min. value | unit | max. value)

0

1

Subcodes

Lenze setting

Information

C00118/1

0

Terminal polarity of digital outputs 1 ... 4

C00118/...
C00118/4

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT