9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 30

Advertising
background image

9400 HighLine | Parameter setting & configuration

Commissioning

Initial commissioning

30

Firmware 1.37 - 09/2006

L

Check & optimise application /DC-bus operation:

1. Traverse axis in manual operation.

• See chapter

Basic drive functions Manual jog

(C 156)

2. Check area boundaries (travel, speed, torque).
3. Traverse axis in automatic operation with set-up speed, possibly together with coupled axes.
4. Check coupling with other motions (master-/slave axes, tools, …).
5. Optimisation of the process at higher speeds.
6. Recording of signal characteristics using the oscilloscope function for the documentation.

• See chapter

Oscilloscope (C 416)

Save & archive project and parameter set:

1.

Save parameter set

.

(C 57)

2. Save »Engineer« project.
3. Deposit a safety copy of the »Engineer« project e.g. on CD ROM in the control cabinet.

Worksteps