TAs for interconnection via electrical shaft

TA "Synchronism with mark synchronisation" | Assignment of the I/O terminals

12.3.2

Assignment of the I/O terminals

12.3.2.1

Setpoint and control signals
The following tables contain the Lenze assignment of the analog and digital inputs for the

technology application "Synchronism".

Analog inputs

Digital inputs

Terminal X3

Signal (Lenze setting)

AI1-

AI1+

-

AI2-

AI2+

-

I/O terminals Analog inputs (C 117)

Terminal X5

Signal (Lenze setting)

DI1

Quick stop

• If DI1 is set to LOW level, the drive is decelerated to standstill within the deceleration

time set for the quick stop function independent of the setpoint selection.

• If the quick stop function is deactivated, the drive is led to the selected setpoint again via

the set acceleration time.

Basic drive functions Quick stop (C 152)

DI2

Connection of reference switch/touch probe sensor for tool synchronisation

DI3

Connection of touch probe sensor for master value synchronisation

DI4

Close clutch

DI5

Reset error

• By means of a LOW-HIGH edge an existing error status can be reset if the cause of the

fault is removed.

DI6

Start trimming

DI7

-

DI8

-

I/O terminals Digital inputs (C 123)

A1+

A1-

A1-

A1R

A2+

A2-

GI

RFR

DI1

DI2

DI3

DI4

DI5

DI6

DI7

DI8