1 function description, 2 filtering logbook entries, Filtering logbook entries – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 437: C 437), 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

437

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Logbook

15.3.1

Function description

The structure of the logbook corresponds to a ring buffer structure:

[15-1] Ring buffer structure

15.3.2

Filtering logbook entries

Before the logbook logs new entries in the ring buffer, the entries are filtered by a

parameterisable filter.
This filter is used to exclude events with a certain error response (fault, warning,

information, etc.) from entry into the logbook.

r

The filter parameters are set under

C00169

by means of a bit mask:

[15-2] Bit mask for event-type filter

r

Example: Bit 6 must be set to "1" to exclude all events with "Information" response

from entry into the logbook:

[15-3] Example: Bit mask for hiding events with "Information" response



Current event

r

As long as free logbook memory capacity is

available, the entries will be saved at the next

free memory location.

r

If all memory locations are occupied, the oldest

entries will be deleted to save new entries.

n

n-1

n-2

0

Meaning:


System error



Information



Warning



Warning locked



Quick stop by trouble



Trouble



Fault



Not assigned

Bit 0

Bit 7

6

5

3 4

2

1

0

7

Meaning:


System error



Information



Warning



Warning locked



Quick stop by trouble



Trouble



Fault



Not assigned

Bit 0

Bit 7

1 0

0

0

0

0

0

6

5

3 4

2

1

0

7

0

Note!

Events with the set "None" response are not entered into the logbook.

Advertising