Internal error (crc code - ram) [0x00690000, Internal error (logbook memory area) [0x00690001, Internal error (lds instance data) [0x00690002 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 455: 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

455

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Error messages of the operating system

Combination memory module/device not possible [0x0068001f]

Combination module in MXI1/device not possible [0x00680020]

Combination module in MXI2/device not possible [0x00680021]

Internal error (CRC code - RAM) [0x00690000]

Internal error (logbook memory area) [0x00690001]

Internal error (LDS instance data) [0x00690002]

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

The memory module used is not supported by the

controller according to the license model.

Plug in supported module and switch the mains.

• Only memory module MM220 or MM330 may be

plugged in the 9400 HighLine.

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

The extension module in the module receptacle MXI1 is

not supported by the controller.

• Remove the extension module and switch the mains.

• Plug in supported extension module and switch the

mains.

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

The extension module in the module receptacle MXI2 is

not supported by the controller.

• Remove the extension module and switch the mains.

• Plug in supported extension module and switch the

mains.

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Serious device error or component failure.

Switch off and on controller.

• Please contact Lenze, if the problem occurs again.

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Serious device error or component failure.

Switch off and on controller.

• Please contact Lenze, if the problem occurs again.

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Serious device error or component failure.

Switch off and on controller.

• Please contact Lenze, if the problem occurs again.