9400 HighLine | Parameter setting & configuration

Motor interface

Initial commissioning | Optimise current controller

The following picture shows a typical saturation characteristic of an MCS motor:

[5-1]

Saturation characteristic: Inductance referring to the inductance for rated current

r

By optimising different current setpoints such a characteristic can be detected per

"trial" and set in

C02853

.

r

The correction by means of this saturation characteristic can be switched off or on via

C02859

.

Distribution of the grid points

r

The saturation characteristic is displayed by 17 points which are distributed linearly on

the X axis.

r

The point 17 represents 100 % of the maximum motor current in the process (

C02855

).

[5-2]

Saturation characteristic: Distribution of the grid points

O

Tip!
The following chapter provides an example for determining the saturation

characteristic.

Example for determining the saturation characteristic

(C 84)

0 %

10 %

20 %

30 %

40 %

50 %

60 %

70 %

80 %

90 %

100 %

0 %

20 %

40 %

60 %

80 %

100 %

120 %

I/I

max

L/L

n

Note!

The saturation characteristic is not only used for the correction of the current

controller but also influences the current controller feedforward control

(

C00074

).

0

6.25

12.5

18.75

25

31.25

37.5

43.75

50

56.25

62.5

68.75

75

81.25

87.5

93.75

100

I

max

Vp
Tn

[V/A]

[ms]

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

[%]