Error messages of the operating system

CAN module (MXI2) RPDO4: Telegram not received or faulty [0x00b00003]

CAN module (MXI2) RPDO5: Telegram not received or faulty [0x00b00004]

CAN module (MXI2) RPDO6: Telegram not received or faulty [0x00b00005]

CAN module (MXI2) RPDO7: Telegram not received or faulty [0x00b00006]

CAN module (MXI2) RPDO8: Telegram not received or faulty [0x00b00007]

Response (Lenze setting printed in bold)

Setting:

C14591/4

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI2: CAN-IN 4

error

• Incorrect PDO telegram length.

• Transmission error.

• PDO time monitoring has released.

• Set the correct telegram length for the CAN master

(transmitter).

• Remove electromagnetic interference (e.g. EMC).

• Select a different time monitoring or switch off time

monitoring.

Response (Lenze setting printed in bold)

Setting:

C14591/5

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI2: CAN-IN 5

error

• Incorrect PDO telegram length.

• Transmission error.

• PDO time monitoring has released.

• Set the correct telegram length for the CAN master

(transmitter).

• Remove electromagnetic interference (e.g. EMC).

• Select a different time monitoring or switch off time

monitoring.

Response (Lenze setting printed in bold)

Setting:

C14591/6

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI2: CAN-IN 6

error

• Incorrect PDO telegram length.

• Transmission error.

• PDO time monitoring has released.

• Set the correct telegram length for the CAN master

(transmitter).

• Remove electromagnetic interference (e.g. EMC).

• Select a different time monitoring or switch off time

monitoring.

Response (Lenze setting printed in bold)

Setting:

C14591/7

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI2: CAN-IN 7

error

• Incorrect PDO telegram length.

• Transmission error.

• PDO time monitoring has released.

• Set the correct telegram length for the CAN master

(transmitter).

• Remove electromagnetic interference (e.g. EMC).

• Select a different time monitoring or switch off time

monitoring.

Response (Lenze setting printed in bold)

Setting:

C14591/8

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI2: CAN-IN 8

error

• Incorrect PDO telegram length.

• Transmission error.

• PDO time monitoring has released.

• Set the correct telegram length for the CAN master

(transmitter).

• Remove electromagnetic interference (e.g. EMC).

• Select a different time monitoring or switch off time

monitoring.