Communicating with the controller

The following interfaces/communication modules can be used to build up communication

between PC and controller:

r

Diagnostic interface X6/

Going online via diagnostic adapter

r

CAN on-board interface/

Going online via system bus (CAN on board)

(C 24)

r

Optional interfaces provided by corresponding communication modules in the module

receptacles MXI1/MXI2 of the controller.

O

Tip!
Detailed information about the individual interfaces can be found in the

corresponding Communication Manuals.

2.2.1

Going online via diagnostic adapter

For the initial commissioning of the controller, you can use, for instance, the diagnostic

adapter offered by Lenze:

Note!

For communication with the controller, at least the control electronics of the

controller must be supplied with 24 V low voltage via plug X2. For detailed

information, please see the Mounting Instructions for the controller.

Note!

Please observe the documentation for the diagnostic adapter!