9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02599

628

Firmware 1.37 - 09/2006

L

C02599

C02607

C02608

C02609

C02610

Parameter | Name:

C02599 | Grinding OFF time

Data type: UNSIGNED_32

Index: 21976

d

= 55D8

h

Basic function "

Brake control

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.2

s

2.0 0.5 s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10

Parameter | Name:

C02607 | BRK_dnState

Data type: INTEGER_32

Index: 21968

d

= 55D0

h

Status of the "

brake control

" basic function (LS_Brake).

Display range

(min. value | unit | max. value)

-2147483648

2147483647

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02608 | BRK_dnTorqueAdd_n

Data type: INTEGER_32

Index: 21967

d

= 55CF

h

Display of the additive torque value of the "

brake control

" basic function (LS_Brake).

Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C02609 | Brake control: Dig. signals

Data type: UNSIGNED_32

Index: 21966

d

= 55CE

h

Display of the boolean signals of the "

brake control

" basic function (LS_Brake).

Selection list

0 FALSE
1 TRUE

Subcodes

Information

C02609/1

BRK_bReleaseBrake

C02609/2

BRK_bStartingTorque2

C02609/3

BRK_bBrakeApplied

C02609/4

BRK_bBrakeTest

C02609/5

BRK_bBrakeGrindIn

C02609/6

BRK_bReleaseBrakeOut

C02609/7

BRK_bBrakeReleased

C02609/8

BRK_bError

C02609/9

BRK_bCInhActive

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02610 | Decel. time - stop function

Data type: UNSIGNED_32

Index: 21965

d

= 55CD

h

Basic function"Stop

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.000

s

1000.000 1.000 s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 1000