C00573, C00574, C00576 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 587: C00577, C00578, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

587

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00573

C00573

C00574

C00576

C00577

C00578

Parameter | Name:

C00573 | Resp. to brake chopper overload

Data type: UNSIGNED_32

Index: 24002

d

= 5DC2

h

Response to release of brake chopper monitoring
Selection list

(Lenze setting printed in bold)

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00574 | Resp. to overtemp. brake resist.

Data type: UNSIGNED_32

Index: 24001

d

= 5DC1

h

Response to release of brake resistor monitoring
Selection list

(Lenze setting printed in bold)

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00576 | Window speed monitoring

Data type: UNSIGNED_32

Index: 23999

d

= 5DBF

h

Monitoring window for speed control error in [%] of nmax
Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 100 %

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00577 | Field weakening controller gain

Data type: UNSIGNED_32

Index: 23998

d

= 5DBE

h

With setting "0", the proportional component is deactivated and an integral-action controller is used.
Setting range

(min. value | unit | max. value)

Lenze setting

0.000

Vs/V

2147483.647 0.000 Vs/V

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 1000

Parameter | Name:

C00578 | Field weak. contr. reset time

Data type: UNSIGNED_32

Index: 23997

d

= 5DBD

h

With setting "240000.0 ms", the integral-action component of the field weakening controller is deactivated.
Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

240000.0 2000.0 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 10