Set motor parameters

To control an electrical machine, the motor parameters must be known.

r

The motor parameters for Lenze motors are known and are already set accordingly by

selecting them from the »Engineer« motor catalog or reading out the ENP.

r

The device command "Set motor parameters" serves to set the motor parameters listed

in the following table for an external motor automatically unless they are known:

O

Tip!
The »Engineer« displays an equivalent circuit diagram with these motor

parameters when you got to the Application parameter tab in the dialog level

OverviewMotor and press the button Other motor data....
The representation of the equivalent circuit diagram depends on the motor control

selected (

C00006

).

Requirements

r

Before the automatic parameter determination is started, the switching performance

of the inverter must have been optimised to ensure a sinusoidal current flow.

Optimise the switching performance of the inverter

(C 73)

r

The motor parameters listed in the following table are excluded from the automatic

determination and must be adapted to the motor used (see motor nameplate) before

the determination.

Note!

Not required if a Lenze motor is operated on the controller!

Parameters

Information

ASM

SM

C00079

Motor - magnetising inductance

;

C00082

Motor - rotor resistance

;

C00084

Motor stator resistance

;

;

C00085

Motor stator leakage induct.

;

;

C00091

Motor - cosine phi

;

C00092

Motor - magnetising current

;

Parameters

Information

C00081

Motor - rated power

C00087

Rated motor speed

C00088

Rated motor current

(The current amount for the procedure is derived from this specification)

C00089

Rated motor frequency

C00090

Rated motor voltage