Standard TAs

Introduction

242

Firmware 1.37 - 09/2006

L

11.1

Introduction

11.1.1

Application examples

Dosing drives

r

Both dosing drives are operated in speed-controlled mode and determine the mix ratio

with their speed:

[11-1] Example: Dosing drives with adjustable mix ratio v

1

/v

2

r

Technical connections/machine parameters:

n

Mains

o

System bus (CAN)

p

Drive 1 with TA "actuator – speed"

q

Drive 2 with TA "actuator – speed"

i = gearbox factor

n = Load reference speed in [rpm]

v = Reference speed in [m/s]

d = roll diameter in [m]

d

1

n

1

v

1

i

1

d

2

n

2

i

2

v

2

Ž



Œ



Parameters

Information

C00011

Motor reference speed

C02520

Gearbox fact. numer. motor

C02521

Gearbox fact. denom. motor

C02542

Load reference speed

Highlighted in grey = display parameter

Parameters

Information

C02524

Feed constant  roll diameter in [m] * π

C02525

Selection of the unit  [m]

Highlighted in grey = display parameter

Load reference speed [min-1] Motor reference speed [min-1]

Gearbox factor

-------------------------------------------------------------------------------

=

Reference speed [m/s] Roll diameter [m] π Load reference speed [min-1]

⋅ ⋅