C01121, C01122, C01123 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 607: 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

607

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C01121

C01121

C01122

C01123

Parameter | Name:

C01121 | Sync cycle time

Data type: UNSIGNED_32

Index: 23454

d

= 5B9E

h

Setting range

(min. value | unit | max. value)

Lenze setting

250

μs

13000 1000 μs

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C01122 | Sync phase position

Data type: UNSIGNED_32

Index: 23453

d

= 5B9D

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

64000 0 μs

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C01123 | Sync window

Data type: UNSIGNED_32

Index: 23452

d

= 5B9C

h

Setting range

(min. value | unit | max. value)

Lenze setting

0

μs

1000 0 μs

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Advertising