9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00597

592

Firmware 1.37 - 09/2006

L

C00597

C00598

C00599

C00600

Parameter | Name:

C00597 | Resp. to motor phase failure

Data type: UNSIGNED_32

Index: 23978

d

= 5DAA

h

Response to release of motor phase failure monitoring
Selection list

(Lenze setting printed in bold)

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00598 | Resp. to open circuit AIN1

Data type: UNSIGNED_32

Index: 23977

d

= 5DA9

h

Response if with master current at AIN1 and mode LifeZero (±4...±20 mA) the current is in the non permitted range

(-4...+4 mA).
Selection list

(Lenze setting printed in bold)

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00599 | Threshold motor phase failure

Data type: INTEGER_32

Index: 23976

d

= 5DA8

h

Threshold for motor phase failure monitoring

• The response when reaching the threshold can be selected in

C00597

.

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

%

10.0 5.0 %

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10

Parameter | Name:

C00600 | Resp. to DC bus overvoltage

Data type: UNSIGNED_32

Index: 23975

d

= 5DA7

h

Response to DC bus overvoltage
Selection list

(Lenze setting printed in bold)

1 Error
2 Fault

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT