1 notes on commissioning using the keypad, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 27

Advertising
background image

L

Firmware 1.37 - 09/2006

27

9400 HighLine | Parameter setting & configuration

Commissioning

Notes on commissioning using the keypad

3.1

Notes on commissioning using the keypad

For motor with electronic nameplate (ENP)

r

A display of the route data offered by ENP via keypad is not provided. The route data

must be edited and optimised individually.

r

In order that the motor does not start unintentionally without adjusting the route data,

the maximum current in the Lenze setting is set to "0 A" in

C00022

.

r

After setting the route data these motor data and the ones read out of the ENP must be

stored with mains failure protection on the memory module of the controller

(

C00002

= "11").

For motor without electronic nameplate (ENP)

r

The motor and route data must be edited and set individually.

r

In order that the motor does not start unintentionally without adjusting the route data,

the maximum current is set to "0 A" in

C00022

as factory adjustment.

r

After the motor and route data are set, they must be stored with mains failure

protection on the memory module of the controller (

C00002

= "11").

Commissioning of the application

r

The application must already be stored on the memory module of the controller.

Otherwise, commissioning with keypad only is not possible.

r

All application parameters which deviated from the factory adjustment, must be

edited individually. For this purpose, the project planner must provide a corresponding

list (including the motor and route data) for the commissioner.

r

In case of a standard set-up the rotor position must be adjusted for synchronous

motors of a third-party manufacturer and Lenze synchronous motors with Stegmann

absolute value encoder.

r

After the parameters are set, they must be stored with mains failure protection on the

memory module of the controller (

C00002

= "11").

Advertising