Diagnostics & error analysis

Error messages of the operating system

Code number assigned twice [0x00900008]

Parameter set: Variant conflict [0x00900009]

No parameters for module in MXI1 [0x0090000a]

No parameters for module in MXI2 [0x0090000b]

Mains voltage switched on [0x00910000]

Mains voltage switched off [0x00910001]

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble : Warning locked … Warning … Information

Cause

Remedy

Code number of the operating system has been assigned

to the application.

Remove error in the application and retransmit the

application to the controller.

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

The firmware has loaded a parameter set the type code

of which does not comply with the type code of the

controller.

Load a suitable parameter set.

Response (Lenze setting printed in bold)

Setting:

C00615/2

(; Adjustable response)

;

None … System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

The parameter set contains no parameters for the

module inserted in MXI1.

Integrate the module inserted in MXI1 into the Engineer

project and then retransmit the parameter set to the

controller.

Response (Lenze setting printed in bold)

Setting:

C00615/3

(; Adjustable response)

;

None … System fault : Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

The parameter set contains no parameters for the

module inserted in MXI2.

Integrate the module inserted in MXI2 into the Engineer

project and then retransmit the parameter set to the

controller.

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

Mains voltage has been switched on.

- (Information only)

Response (Lenze setting printed in bold)

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning : Information

Cause

Remedy

Mains voltage has been switched off.

- (Information only)