9400 HighLine | Parameter setting & configuration

Motor interface

Initial commissioning | Parameterise motor encoder

70

Firmware 1.37 - 09/2006

L

5.1.5

Parameterise motor encoder

O

Tip!
Detailed information on the encoder evaluation and on the use of a separate

position encoder can be found in the following main chapter "

Encoder evaluation

".

(C 108)

r

The motor encoder can also be parameterised in the »Engineer« on the Application

parameter tab in the dialog level OverviewMotor.

r

The following table shows the required settings for different encoder types:

Encoder type: Resolver

Tamagawa

CDD50

ITD21

ITD22

SCS70

SCM70

SRS50

SRM50

ECN1313

EQN1325

EQI1329

Motor type:

MCS

MCA

MDxKS

MDXMA

MCA

MDFQA

LMR

MDFQA

LMR

MDxKS

MCS

MCA

MCS

MCA

MCS

MCA

C00495

Motor encoder

0

Resolver

1

Encoder

C00080

Resolver - pole pair

number

1

-

-

-

-

-

-

-

C00422

Encoder - type

-

0

Incremental encoder

(TTL signal)

1

Sin/cos

encoder

2

Absolute value

encoder (Hiperface)

3

Absolute value

encoder (EnDat)

C00420

Encoder - PPR

-

2048

512

1024

2048

32

C00421

Encoder - voltage

-

5 V

8 V

5 V



Danger!

When using the encoder/resolver as motor encoder:
In case of an error as safe motor operation cannot be ensured anymore. Thus, the

"Fault" response (Lenze setting) should be set permanently for the (open circuit)

monitoring of the encoder/resolver!

C00580

: Response to open circuit of encoder

C00586

: Response to open circuit of resolver

C00601

: Response to communication error of encoder