C00022, C00034, C00050 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 548: C00051, C00052, C00053, C00054, Must be set later in, Must be higher or the same as, 15 a") in

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00022

548

Firmware 1.37 - 09/2006

L

C00022

C00034

C00050

C00051

C00052

C00053

C00054

Parameter | Name:

C00022 | Maximum current

Data type: UNSIGNED_32

Index: 24553

d

= 5FE9

h

Note: In order that the motor does not start unintentionally without adjusting the route data, the maximum

current in the Lenze setting is set to "0 A"!
Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A

21474836.47 0.00 A

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT Scaling factor: 100

Parameter | Name:

C00034 | Config. analog input 1

Data type: UNSIGNED_32

Index: 24541

d

= 5FDD

h

Selection list

(Lenze setting printed in bold)

0 -10 ... +10 V
1 -20...-4 mA, +4...+20 mA
2 -20 ... +20 mA

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00050 | Speed setpoint

Data type: INTEGER_32

Index: 24525

d

= 5FCD

h

Display range

(min. value | unit | max. value)

-480000

rpm

480000

Subcodes

Information

C00050/1

Speed setpoint 1

C00050/2

Speed setpoint 2

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00051 | Actual speed

Data type: INTEGER_32

Index: 24524

d

= 5FCC

h

Display range

(min. value | unit | max. value)

-480000

rpm

480000

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00052 | Motor voltage

Data type: UNSIGNED_32

Index: 24523

d

= 5FCB

h

Display range

(min. value | unit | max. value)

0

V

2147483647

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00053 | DC bus voltage

Data type: UNSIGNED_32

Index: 24522

d

= 5FCA

h

Display range

(min. value | unit | max. value)

0

V

2147483647

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00054 | Motor current

Data type: UNSIGNED_32

Index: 24521

d

= 5FC9

h

Display range

(min. value | unit | max. value)

0.00

A

500.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100