9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 323

Advertising
background image

L

Firmware 1.37 - 09/2006

323

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Electronic gearbox" | Brake control

r

Parameter setting: Tab Application parameter  Dialog level Overview  Brake control

Parameters

Lenze setting

Value Unit

C02580

Operating mode - brake

Brake control off

C02581

Brake activation threshold

50 rpm

C02582

Brake resp. to pulse inhibit

Activate the brake immediately

C02583

Status input monitoring

Not active

C02585

Brake control polarity

Not inverted

C02586

Starting torque 1

0.00 Nm

C02587

Starting torque 2

0.00 Nm

C02588

Source of starting torque

Starting torque 1/2

C02589

Brake closing time

100 ms

C02590

Brake opening time

100 ms

C02591

Waiting time - status monit.

100 ms

C02593

Waiting time - brake active.

0.000 s

C02594

Test torque

0.00 Nm

C02595

Permissible angle of rotation

5 °

C02596

Grinding speed

100 rpm

C02597

Accel./decel. time - grinding

1.000 s

C02598

Grinding ON time

0.5 s

C02599

Grinding OFF time

0.5 s

Control/setpoint inputs of the function

Signal configuration

Lenze setting

Control/setpoint input

(Multiplexer parameters)

FALSE  Release brake

C03165/1

FALSE  Activate starting torque 2

C03165/2

FALSE  Brake status signal

C03165/3

FALSE  Activate brake test

C03165/4

FALSE  Grind brake

C03165/5

0 %  Additional torque

C03166

Advertising