Parameter list | C02703

C02703

C02704

C02705

C02706

C02707

Parameter | Name:

C02703 | Max. speed

Data type: INTEGER_32

Index: 21872

d

= 5570

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s

214748.3647 3600.0000 Unit/s

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02704 | Max. speed [rpm]

Data type: INTEGER_32

Index: 21871

d

= 556F

h

Basic function "

Limiter

"

Display range

(min. value | unit | max. value)

0.0

rpm

214748364.7

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10

Parameter | Name:

C02705 | Max. acceleration

Data type: INTEGER_32

Index: 21870

d

= 556E

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit/s²

214748.3647 3600.0000 Unit/s²

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02706 | Min. S-ramp time

Data type: UNSIGNED_32

Index: 21869

d

= 556D

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

10000 100 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02707 | Permissible direction of rot.

Data type: UNSIGNED_32

Index: 21868

d

= 556C

h

Basic function "

Limiter

"

Selection list

(Lenze setting printed in bold)

0 Positive and negative
1 Positive only
2 Negative only

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT