L

Firmware 1.37 - 09/2006

609

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C01191

C01191

C01192

C01193

C01194

C01195

Parameter | Name:

C01191 | Temperature for spec. characteristic

Data type: UNSIGNED_32

Index: 23384

d

= 5B58

h

The special thermal sensor characteristic is selected by setting

C01190

="1"

Setting range

(min. value | unit | max. value)

0

°C

255

Subcodes

Lenze setting

Information

C01191/1

25 °C

Value 1 for spec. thermal sensor characteristic

C01191/2

150 °C

Value 2 for spec. thermal sensor characteristic

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C01192 | Resistor for spec. characteristic

Data type: UNSIGNED_32

Index: 23383

d

= 5B57

h

The special thermal sensor characteristic is selected by setting

C01190

="1"

Setting range

(min. value | unit | max. value)

0

Ohm

30000

Subcodes

Lenze setting

Information

C01192/1

1000 Ohm

Value 1 for spec. thermal sensor characteristic

C01192/2

2225 Ohm

Value 2 for spec. thermal sensor characteristic

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C01193 | Motor temp. feedback system

Data type: UNSIGNED_16

Index: 23382

d

= 5B56

h

Selection of feedback system for motor temperature detection.
Selection list

(Lenze setting printed in bold)

0 Speed feedback
1 Resolver X7
2 Encoder X8
3 Encoder module in MXI1
4 Encoder module in MXI2

;

Read access ; Write access ; CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C01194 | Motor operating temperature

Data type: INTEGER_32

Index: 23381

d

= 5B55

h

Setting range

(min. value | unit | max. value)

Lenze setting

1

°C

200 140 °C

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C01195 | Influence winding I²xt mon.

Data type: UNSIGNED_32

Index: 23380

d

= 5B54

h

I

2

xt motor monitoring: Influence of the winding temperature

• By setting "0 %" the time constant for the winding is not considered and the thermal model is only calculated

with the time constant set for the housing/steel plates.

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 0 %

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT