9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 347

Advertising
background image

L

Firmware 1.37 - 09/2006

347

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Synchronism with mark synchronisation" | "Synchronism" mode"

TP profile parameters

r

Parameter setting: Tab Application parameter  Dialog level Overview  TP profile

parameter

r

Configuration: Tab FB editor  FB MarkSynchronizationShaft

TP interface

r

Parameter setting: Tab Application parameter  Dialog level Overview  TP interface

Parameters

Lenze setting

Value Unit

C03620

Positioning mode

0

C03621

Deactivation mode

0

C03623/1

Positive speed

3600.0000 Unit/t

C03623/2

Negative speed

3600.0000 Unit/t

C03626/1

Acceleration ramp

1.000 s

C03626/2

Deceleration ramp

1.000 s

C03626/3

Stop ramp

1.000 s

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE  Activate master value TP correction

C03058/12

Parameters

Lenze setting

Value Unit

C02810/3

Signal delay TP3

0 μs

C03022

Edge evaluation of positive edge

TRUE

C03024

Edge evaluation of negative edge

FALSE

Advertising