3 logbook, Logbook, Logbook (c 436) – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 436: Logbook, please see the chapter, C 436), 9400 highline | parameter setting & configuration

Advertising
background image

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Logbook

436

Firmware 1.37 - 09/2006

L

15.3

Logbook

The integrated logbook function of the controller chronologically logs important events

within the system and plays an important role for troubleshooting and controller

diagnostics.

Events that can be logged
The following events can be logged in the logbook:

r

Error messages of the operating system

(C 443)

r

Error messages generated by the application

r

Controller enable

r

Starting / stopping the application

r

Loading/saving of parameter sets, loading of the Lenze setting

r

Transmitting an application or firmware to the controller

r

Connection/disconnection of the controller

r

Formatting of the file system

O

Tip!
Use a parameterisable filter to exclude certain events from logbook entry.

Filtering logbook entries

(C 437)

Information saved
For each event, the following information are saved in the logbook:

r

Type of response (e.g. fault, warning or information) to the event

r

Module that activated the event (e.g. MCTRL or TEMPCONTROL).

r

Event

r

Date/time (for memory module with real-time clock)

r

Value of power-on time meter

Memory depth
The number of possible logbook entries depends on the memory module used:

r

MM1xx, MM2xx: 7 entries

r

MM3xx, MM4xx: 439 entries

Advertising