Can module (mxi1): life guarding error [0x009e0020, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 507

Advertising
background image

L

Firmware 1.37 - 09/2006

507

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Error messages of the operating system

CAN module (MXI1): Heartbeat error index 28 [0x009e001b]

CAN module (MXI1): Heartbeat error index 29 [0x009e001c]

CAN module (MXI1): Heartbeat error index 30 [0x009e001d]

CAN module (MXI1): Heartbeat error index 31 [0x009e001e]

CAN module (MXI1): Heartbeat error index 32 [0x009e001f]

CAN module (MXI1): Life guarding error [0x009e0020]

Response (Lenze setting printed in bold)

Setting:

C13613/28

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI1: No heartbeat

telegram received from node 28.

See remedy for "

Heartbeat error index 1

".

Response (Lenze setting printed in bold)

Setting:

C13613/29

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI1: No heartbeat

telegram received from node 29.

See remedy for "

Heartbeat error index 1

".

Response (Lenze setting printed in bold)

Setting:

C13613/30

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI1: No heartbeat

telegram received from node 30.

See remedy for "

Heartbeat error index 1

".

Response (Lenze setting printed in bold)

Setting:

C13613/31

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI1: No heartbeat

telegram received from node 31.

See remedy for "

Heartbeat error index 1

".

Response (Lenze setting printed in bold)

Setting:

C13613/32

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI1: No heartbeat

telegram received from node 32.

See remedy for "

Heartbeat error index 1

".

Response (Lenze setting printed in bold)

Setting:

C13614

(; Adjustable response)

:

None … System fault ; Fault ; Trouble ; Quick stop by trouble ; Warning locked ; Warning ; Information

Cause

Remedy

CANopen communication module in MXI1: Cyclic node

monitoring

• Slave response: Maximum time between two node

guarding telegrams (remote transmission request

telegram) from the master has been exceeded.

Select a different life guarding monitoring time or switch

off monitoring.

Advertising