9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 441

Advertising
background image

L

Firmware 1.37 - 09/2006

441

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Monitoring

Warning thresholds
Some of the monitoring functions are activated if a defined warning threshold (e.g.

temperature) have been exceeded.

r

The corresponding preset threshold values can be changed via the following

parameters:

Parameters

Information

C00120

Motor overload protection (I²xt)

C00121

Warning threshold - motor temperature

C00122

Warning threshold - heatsink temperature

C00123

Warning threshold - device utilisation

C00126

Warning threshold - CPU temperature

C00127

Warning threshold - motor overload

C00128

Thermal motor time constant

C00132

Max. temperature of brake resistor

C00174

Undervoltage (LU) threshold

C00185

Threshold - mains recovery recognition

C00576

Window - speed monitoring

C00596

Threshold of maximum speed reached

C00599

Threshold - motor phase failure

C00620

Max. motor current threshold

Advertising