C00695, C00696, C00697 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 598: C00698, C00730, C00731, C00732, C00733, C00734, C00735

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00695

598

Firmware 1.37 - 09/2006

L

C00695

C00696

C00697

C00698

C00730

C00731

C00732

C00733

C00734

C00735

Parameter | Name:

C00695 | Total torque setpoint

Data type: INTEGER_32

Index: 23880

d

= 5D48

h

Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00696 | Torque setpoint

Data type: INTEGER_32

Index: 23879

d

= 5D47

h

Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00697 | Filtered torque setpoint

Data type: INTEGER_32

Index: 23878

d

= 5D46

h

Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00698 | Actual torque

Data type: INTEGER_32

Index: 23877

d

= 5D45

h

Display range

(min. value | unit | max. value)

-200.00

%

200.00

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00730 | GDO common parameter

Data type: INTEGER_32

Index: 23845

d

= 5D25

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00731 | GDO channel 1/trigger 1

Data type: INTEGER_32

Index: 23844

d

= 5D24

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00732 | GDO channel 2/trigger 2

Data type: INTEGER_32

Index: 23843

d

= 5D23

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00733 | GDO channel 3

Data type: INTEGER_32

Index: 23842

d

= 5D22

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00734 | GDO channel 4

Data type: INTEGER_32

Index: 23841

d

= 5D21

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00735 | GDO channel 5

Data type: INTEGER_32

Index: 23840

d

= 5D20

h

This code is used internally by the controller and must not be overwritten by the user!