Parameter reference

Parameter list | C00120

C00120

C00121

C00122

C00123

C00126

C00127

Parameter | Name:

C00120 | Mot. overload protection (I²xt)

Data type: UNSIGNED_32

Index: 24455

d

= 5F87

h

Threshold for I

2

x t disconnection

• Disconnection is carried out if the thermal motor load (

C00066

) is higher than the set threshold.

• A 100 % thermal motor load corresponds to a permanently flowing rated motor current
Setting range

(min. value | unit | max. value)

Lenze setting

0

%

200 105 %

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00121 | Motor temp. warning threshold

Data type: UNSIGNED_32

Index: 24454

d

= 5F86

h

Temperature threshold for motor temperature advance warning

• The reaction for reaching the threshold can be selected in

C00584

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

°C

150 120 °C

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT

Parameter | Name:

C00122 | Heatsink temp. warn. threshold

Data type: UNSIGNED_32

Index: 24453

d

= 5F85

h

Temperature threshold for heatsink temperature advance warning

• The reaction for reaching the threshold can be selected in

C00582

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

°C

85 85 °C

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00123 | Device util. warning threshold

Data type: UNSIGNED_32

Index: 24452

d

= 5F84

h

Adjustable threshold for I x t advance warning

• The advance warning is sent if the controller load (

C00064

) is higher than the set threshold.

• The reaction for reaching the threshold can be selected in

C00604

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

100 90 %

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00126 | CPU temp. warning threshold

Data type: UNSIGNED_32

Index: 24449

d

= 5F81

h

Temperature threshold for advance warning of CPU temperature on the control card

• The reaction for reaching the threshold can be selected in

C00589

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

°C

85 70 °C

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00127 | Mot. overload warning threshold

Data type: UNSIGNED_32

Index: 24448

d

= 5F80

h

Adjustable threshold for I

2

x t advance warning

• The advance warning is sent if the thermal motor load (

C00066

) is higher than the set threshold.

• The reaction for reaching the threshold can be selected in

C00606

.

Setting range

(min. value | unit | max. value)

Lenze setting

0

%

200 100 %

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM ; MOT