3 signal types & scaling, 9400 highline | paramete r setting & configuration, Introduction signal types & scaling – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 25

Advertising
background image

L

Fir

m

w

are

1.37 - 09/2006

25

9400 HighLine | Paramete

r setting & configuration

Introduction

Signal types &

scaling

2.3

Signal types & scaling

It is very helpful for the parameter setting & configuration of the controller to know the signal types and their scaling listed in the following table, which serve to

process physical sizes (e.g. a speed or position) in a function block configuration.

Signal type

Unit

Connection

symbol in

the FB editor

Resolution

Scaling

external ≡ internal

Range

Number of

decimal

positions

Identifier

suffix

Position

Increments

u

/ w

32 bits

1 motor revolution ≡ 2

16

increments

-2

31

... 2

31

-1 increments

3

_p

Speed

rpm

s

/ t

16 bits

15000 rpm ≡ 2

14

≡ 16384

± 30000.0 rpm

1

_v

x

32 bits

15000 rpm ≡ 2

26

≡ 67108864

± 480000.0 rpm

1

_s

Speed variation/time

rpm/s

v

32 bits

15000000 rpm/s ≡ 2

22

≡ 4194304

± 7.69 * 10

9

rpm/s

3

_x

Scaled signal

%

z

32 bits

100 % ≡ 2

30

≡ 1073741824

± 200.00 %

2

_n

y

16 bits

100 % ≡ 2

14

≡ 16384

± 199.99 %

2

_a

Control/status signal

{

1 bit

0 ≡ FALSE; 1 ≡ TRUE

0 / 1

0

Time

s

|

28 bits

0 ... 268435.456 s

3

Status word

|

32 bits

-2147483648 ... 2147483647

(0000 0000

hex

... FFFF FFFF

hex

)

0

Not standardised

|

O

Tip!
Only inputs/outputs of the same signal type (with the same

connection symbol) can be connected in the function block editor of

the »Engineer«.
Non-standardised inputs/outputs can be connected if the input and

output have the same resolution.