4 master value trimming, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 349

Advertising
background image

L

Firmware 1.37 - 09/2006

349

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Synchronism with mark synchronisation" | "Synchronism" mode"

12.3.5.4

Master value trimming

[12-30] "Master value trimming" function in the signal flow (schematic diagram)

This function serves to adjust the master value.

r

Parameter setting: Tab Application parameter  Dialog level Overview  Synchronism



Master value trimming

r

Configuration: Tab FB editor  FB Trimming

n

Master value with clutch

o

Master value with trimming

Œ



M

v

Slave

Real master/

Virtual master

C03006 = 0

v

t

Dj

Dj

Dj

TP

TP

Parameters

Lenze setting

Value Unit

C03674

Master value with clutch

- Unit

C03026

Activate trimming

Deactivated

C03676

Adjustable range

0.0000 Unit/t

C03685

Positioning mode

0

C03686

Deactivation mode

1

C03688/1

Positive speed

1000.0000 Unit/t

C03688/2

Negative speed

1000.0000 Unit/t

C03691/1

Acceleration ramp

0.500 s

C03691/2

Deceleration ramp

0.500 s

C03691/3

Stop ramp

1.000 s

C03723

Master value with trimming

- Unit

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

FALSE  Start trimming

C03058/15

C03026  Activate trimming

C03058/16

FALSE  Set trimming setpoint to 0

C03058/17

Advertising