Diagnostics & error analysis

Error messages of the operating system

Safety module has been removed [0x00680007]

Control card is defective [0x00680008]

Power section is defective [0x00680009]

MXI1: Module is defective or missing [0x0068000a]

MXI2: Module is defective or missing [0x0068000b]

Memory module is defective or missing [0x0068000c]

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

You have tried to remove or change the safety module

during operation.

Switch off the controller, plug in safety module and

switch on the controller again.

• If the error occurs again, the safety module is

defective and must be replaced.

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Operating system could not identify the control card.

Please contact Lenze.

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Operating system could not identify the power stage.

Please contact Lenze.

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Operating system could not identify extension module in

module receptacle MXI1.

• Use a different extension module.

• Please contact Lenze.

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Operating system could not identify extension module in

module receptacle MXI2.

• Use a different extension module.

• Please contact Lenze.

Response (Lenze setting printed in bold)

…

None : System fault … Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Operating system could not identify the memory

module.

• Use a different memory module.

• Please contact Lenze.