C00275, C00276, C00280 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 567: C00308, C00309, C00310, C00311, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

567

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00275

C00275

C00276

C00280

C00308

C00309

C00310

C00311

Parameter | Name:

C00275 | Signal source - speed setpoint

Data type: UNSIGNED_16

Index: 24300

d

= 5EEC

h

Selection list

(Lenze setting printed in bold)

0 SpeedAdd signal
1 Differentiated PosSet signal

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00276 | Signal source - torque setpoint

Data type: UNSIGNED_16

Index: 24299

d

= 5EEB

h

Selection list

(Lenze setting printed in bold)

0 TorqueAdd/AccAdd signal
1 Differentiated SpeedSet signal
2 2x diff. PosSet signal

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00280 | Filter time const. DC detection

Data type: UNSIGNED_32

Index: 24295

d

= 5EE7

h

Setting range

(min. value | unit | max. value)

Lenze setting

1.0

ms

1000.0 25.0 ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10

Parameter | Name:

C00308 | Service code

Data type: UNSIGNED_16

Index: 24267

d

= 5ECB

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00309 | Service code

Data type: UNSIGNED_32

Index: 24266

d

= 5ECA

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00310 | Service code

Data type: UNSIGNED_8

Index: 24265

d

= 5EC9

h

This code is used internally by the controller and must not be overwritten by the user!

Parameter | Name:

C00311 | CAN TPDO1 mask byte x

Data type: BITFIELD_8

Index: 24264

d

= 5EC8

h

A mask can be parameterised for each byte of the TPDO1 in the assigned subcode.

• In case of an event-controlled PDO transmission, only the masked bits will be considered for event control.

• Mask "0x0" means that no bit of the corresponding byte activates PDO transmission.

• Mask "0xff" means that each bit of the corresponding byte can activate PDO transmission.
Value is bit-coded:

Bit 0 Mask bit 0

... ...

Bit 7 Mask bit 7

Subcodes

Lenze setting

Information

C00311/1

0x00

Mask for byte 1 ... byte 8 of TPDO1

C00311/...
C00311/8

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT