7 system block "ls_driveinterface, Ls_driveinterface, Is set to true – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 60: Or via the device com, 9400 highline | parameter setting & configuration, Drive interface system block "ls_driveinterface

Advertising
background image

9400 HighLine | Parameter setting & configuration

Drive interface

System block "LS_DriveInterface"

60

Firmware 1.37 - 09/2006

L

4.7

System block "LS_DriveInterface"

The system block LS_DriveInterface displays the drive interface in the function block

editor.

Inputs

Input

DIS code | Data type

Information/possible settings

DI_bSetCInh

C02549/1

| BOOL

Set/remove controller inhibit

(C 44)

TRUE Set controller inhibit.

DI_bResetError1

C02548/1

| BOOL

DI_bResetError2

C02548/2

| BOOL

DI_bResetError3

C02548/3

| BOOL

Error message reset (acknowledgement)

• This function resets an active error message, if the cause of the error message has

been eliminated.

• The three inputs are linked via a logic OR gate.

TRUE Reset (acknowledge) error message.

DI_bSetExternError

C02548/4

| BOOL

Activation of error message "External error".

Monitoring of external events (C 44)

TRUE Activate fault message with the response selected in

C00581

.

DI_bSwitchOn

C02549/4

| BOOL

Deactivate switch-on inhibit

• If the automatic restart is inhibited (

C00142

= "0"), the state machine remains in

the "Device is ready to switch on" state after mains switching.

State "Device is ready to switch on" (C 47)

FALSEÊTRUE The switch-on inhibit is deactivated and the controller changes to

the "Device is switched on" device state.

LS_DriveInterface

DI_dnState

DI_bSetCInh

DI_bResetError1

DI_bSetExternError

DI_bSwitchOn

DI_bReadyToSwitchOn

DI_bReady

DI_bFailActive

DI_bImpActive

DI_bCInhActive

DI_bUVDetected

DI_bMainSupplyOk

DI_bWarningActive

DI_bOVDetected

DI_bOperationEnabled

³ 1

DI_bResetError2

DI_bResetError3

DI_dwErrorCode

DI_AxisData

Advertising