9400 HighLine | Parameter setting & configuration

Basic drive functions

Quick stop | Activating/Deactivating quick stop

154

Firmware 1.37 - 09/2006

L

9.3.2

Activating/Deactivating quick stop

Quick stop through the application is activated/deactivated via the three inputs

QSP_bActivate1...3 of the system block

LS_Quickstop

.

(C 155)

r

The three control inputs are linked via a logic OR gate, i.e. in order to activate quick stop,

only one of the three inputs must be set to TRUE. To deactivate quick stop, though, all

three inputs must be reset to FALSE.

r

The control inputs can be linked with terminals (digital inputs) and/or process data in

the function block editor.

Further options for activating quick stop

r

Via controller command "Activate quick stop" (

C00002

= "45"), e.g. via a corresponding

SDO of a higher-level control, an HMI or the »Engineer«.

r

Via the o key at the keypad, unless the Lenze setting of

C00469

(assignment of the

key) has been changed.

r

Through the response "quick stop by trouble" parameterised for monitoring.

Note!

In the standard technology applications the control input QSP_bActivate1 is

linked with the digital input DI1 in the Lenze setting.