Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 22

Advertising
background image

9400 HighLine | Parameter setting & configuration

Introduction

Communicating with the controller

22

Firmware 1.37 - 09/2006

L

Preconditions:

r

The diagnostic adapter is connected to diagnostic interface X6 on the controller and to

a free USB port on the PC.

r

The driver required for the diagnostic adapter is installed.

r

The control electronics of the controller is supplied with 24 V low voltage via plug X2.

M

How to build up an online connection via the diagnostic adapter:

1. Select the 9400 HighLine controller to which you want to build up an online

connection in the Project view of the »Engineer«:

2. Click the icon or select the command OnlineGo online.

• If no online connection has been configured for the selected controller so far,

the Assignment of offline controllers dialog box will be displayed:

• The dialog box also appears if the online connection is built up via the command

OnlineGo online instead of using the toolbar icon.

3. Select the entry "Diagnostic adapter" from the Bus connection list field.

Advertising