9400 HighLine | Parameter setting & configuration

Drive interface

Device states

48

Firmware 1.37 - 09/2006

L

Auto-start option 0: Auto restart inhibited after mains connection

r

When the automatic start option 0 has been selected, the controller inhibit must be

explicitly reset after the mains is switched on so that the controller status changes

from "Device is ready to switch on" to "Device is switched on":

[4-13] State change when the auto restart is inhibited (C00142 = "0")

4.5.4

State "Device is switched on"

The drive is in this device state when the DC-bus voltage is applied and the controller is still

inhibited by the user (controller inhibit).

r

The bus systems are running and the terminals and encoders are evaluated.

r

The monitoring modes are active.

r

The controller can be parameterised yet and device commands can be executed in a

limited way.

r

The application is basically executable.

r

The function of the user task can be used.
– Condition: The application has started (status display in

C02108

).

r

The basic drive functions cannot be used yet.

r

When the controller is inhibited, the motor creates a torque.




Controller pulses are inhibited

Controller pulses are enabled

n
o

With controller inhibit during power-on

Without controller inhibit during power-on

RFR

Œ

0

1

RFR

RFR

RFR

t

t



Initialisation

Switched on

Operation

Ready to switch on

Initialisation

Switched on

Operation

Ready to switch on

LED DRIVE READY

LED DRIVE ERROR

Display in

C00183

OFF

90: Device is ready to switch on.