1 master value processing, 9400 highline | parameter setting & configuration – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 309

Advertising
background image

L

Firmware 1.37 - 09/2006

309

9400 HighLine | Parameter setting & configuration

TAs for interconnection via electrical shaft

TA "Electronic gearbox" | Operating mode "Electronic gearbox"

12.2.5.1

Master value processing

[12-13] "Master value processing" function in the signal flow (schematic diagram)

r

Parameter setting: Tab Application parameter  Dialog level Overview  Electronic

gearbox

r

Parameter setting: Tab Application parameter  Dialog level Overview  Electronic

gearbox  Master value processing

r

Configuration: Tab FB editor  FB GearElectricalShaft

n

Master value

o

Master value with stretch factor

M

v

Slave

Real master/

Virtual master

v

t

Dj

C03006 = 0

Œ



Parameters

Lenze setting

Value Unit

C03957

Master value

- Unit/t

C03000

Stretch factor - numerator

1000000000

C03001

Stretch factor - denominator

1000000000

C03673

Master value with stretch factor

- Unit/t

Parameters

Lenze setting

Value Unit

C03025

Master value - direction of rotation

Not inverted

Setpoint inputs of the function

Signal configuration

Lenze setting

Setpoint input

(Multiplexer parameters)

C03000  Stretch factor - numerator

C03050/1

C03001  Stretch factor - denominator

C03050/2