C00270, C00271, C00272 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 566: C00273, C00274, C00270/1, C00270/2, C00271/1, C00271/2, C00272/1

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C00270

566

Firmware 1.37 - 09/2006

L

C00270

C00271

C00272

C00273

C00274

Parameter | Name:

C00270 | Freq. - current setpoint filter

Data type: UNSIGNED_32

Index: 24305

d

= 5EF1

h

Setting range

(min. value | unit | max. value)

1.0

Hz

1000.0

Subcodes

Lenze setting

Information

C00270/1

200.0 Hz

Freq. current setpoint filter 1

C00270/2

400.0 Hz

Freq. current setpoint filter 2

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10

Parameter | Name:

C00271 | Width - current setpoint filter

Data type: UNSIGNED_32

Index: 24304

d

= 5EF0

h

Setting range

(min. value | unit | max. value)

0.0

Hz

500.0

Subcodes

Lenze setting

Information

C00271/1

20.0 Hz

Width current setp. filter 1

C00271/2

40.0 Hz

Width current setp. filter 2

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10

Parameter | Name:

C00272 | Depth - current setpoint filter

Data type: UNSIGNED_32

Index: 24303

d

= 5EEF

h

With the setting "0 dB" the current setpoint filter is deactivated
Setting range

(min. value | unit | max. value)

0

db

100

Subcodes

Lenze setting

Information

C00272/1

0 db

Depth current setp. filter 1

C00272/2

0 db

Depth current setp. filter 2

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C00273 | Moment of inertia

Data type: UNSIGNED_32

Index: 24302

d

= 5EEE

h

Setting range

(min. value | unit | max. value)

0.00

kg cm²

10000.00

Subcodes

Lenze setting

Information

C00273/1

0.14 kg cm²

Motor moment of inertia

C00273/2

0.00 kg cm²

Load moment of inertia

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 100

Parameter | Name:

C00274 | Max. acceleration change

Data type: UNSIGNED_32

Index: 24301

d

= 5EED

h

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

%/ms

400.0 400.0 %/ms

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10