Example for determining the saturation characteristic

Given values:

r

Rated motor current: 5 A

r

Maximum motor current: 20 A

r

Maximum process current: 15 A (must be set later in

C00022

)

Procedure:

1. Deactivate correction (

C02859

= "off").

2. Set the maximum current up to which the motor is to be operated in the process in

C02855

(in this example "15 A").

– The value set in

C02855

must be higher or the same as

C00022

.

3. Adjust the current controller with different current setpoints and note the

corresponding settings for Vp and Tn.
– The procedure for the adjustment is described in the chapter "

Optimise current

controller

".

– The current setpoints that are to be set for the prevailing adjustment in

C00022

result from the scaling of the maximum process current to the X axis of the

saturation characteristic.

– Which points are required to display the saturation characteristic with a sufficient

quality, varies from motor to motor and must therefore be detected individually.

– For this example currents have been selected which are situated on the grid points

5, 9, 13 and 15 a measurement has been carried out at rated motor current:

[5-3]

Saturation characteristic: Distribution of the grid points

n

Rated motor current

o

Maximum process current (≡ 100 %)

Œ



15 A

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

7.5 A

3.75 A

11.25 A

12.38 A

5 A

0

6.25

12.5

18.75

25

31.25

37.5

43.75

50

56.25

62.5

68.75

75

81.25

87.5

93.75

100

0 A

I

max

[%]

Vp
Tn

[V/A]

[ms]

1

Specifications for adjustment

Measured values

Grid point

Scaling

Setting C00022

Vp [V/A]

Tn [ms]

5

0.25 * 15 A =

3.75 A

13

6.5

9

0.5 * 15 A =

7.5 A

8

4

13

0.75 * 15 A =

11.25 A

5

2.5

15

0.875 * 15 A =

12.38 A

4

2

17

1.0 * 15 A =

15 A

3

1.7

Rated motor current =