Firmware 1.37 - 09/2006

641

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02712

C02712

C02713

C02714

C02715

Parameter | Name:

C02712 | Decel. time lim. speed

Data type: UNSIGNED_32

Index: 21863

d

= 5567

h

Basic function "

Limiter

"

Display range

(min. value | unit | max. value)

0

ms

10000

Subcodes

Information

C02712/1

Deceleration times for limited speed 1 ... 4

C02712/2
C02712/3
C02712/4

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02713 | Max. dist. manual control

Data type: UNSIGNED_32

Index: 21862

d

= 5566

h

Basic function "

Limiter

"

Setting range

(min. value | unit | max. value)

Lenze setting

0.0000

Unit

214748.3647 360.0000 Unit

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT Scaling factor: 10000

Parameter | Name:

C02714 | Max. dist. manual control

Data type: UNSIGNED_32

Index: 21861

d

= 5565

h

Basic function "

Limiter

"

Display range

(min. value | unit | max. value)

0

Incr.

2147483647

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02715 | Limitation active

Data type: UNSIGNED_32

Index: 21860

d

= 5564

h

Basic function "

Limiter

"

Selection list

(display only)

0 Deactivated
1 Activated

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT