Project is not available [0x008c000a, Required license missing [0x008c000b, Mxi1: module missing or incompatible [0x008c000d – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 493: Mxi2: module missing or incompatible [0x008c000e, 9400 highline | parameter setting & configuration

Advertising
background image

L

Firmware 1.37 - 09/2006

493

9400 HighLine | Parameter setting & configuration

Diagnostics & error analysis

Error messages of the operating system

Project is not available [0x008c000a]

Required license missing [0x008c000b]

MXI1: Module missing or incompatible [0x008c000d]

MXI2: Module missing or incompatible [0x008c000e]

MXI1: PROFIBUS module missing or incompatible [0x008c000f]

MXI2: PROFIBUS module missing or incompatible [0x008c0010]

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Application not available.

• Download application with the Engineer

• Switch off controller and use a different memory

module with an existing application.

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Memory module could not be initialised.

Two possibilities:

• Use the Engineer to download and activate an

application suitable for the memory module.

• Switch off controller and use memory module

suitable for the application.

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

The extension module in module receptacle MXI1 is

incompatible with the application.

Use extension module supported by the application.

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

The extension module in module receptacle MXI2 is

incompatible with the application.

Use extension module supported by the application.

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

The communication module E94AYCPM (PROFIBUS) in

module receptacle MXI1 is incompatible with the

application.

Use communication module supported by the

application.

Response (Lenze setting printed in bold)

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

The communication module E94AYCPM (PROFIBUS) in

module receptacle MXI2 is incompatible with the

application.

Use communication module supported by the

application.

Advertising