C02716, C02717, C02718 – Lenze E94AxHE Servo Drives 9400 HighLine (Firmware 01-37) User Manual

Page 642: C02719, C02716/1, C02716/2, C02716/3, Parameterised in, Takes place, The response parameterised in

Advertising
background image

9400 HighLine | Parameter setting & configuration

Parameter reference

Parameter list | C02716

642

Firmware 1.37 - 09/2006

L

C02716

C02717

C02718

C02719

Parameter | Name:

C02716 | Resp. to limitation

Data type: UNSIGNED_32

Index: 21859

d

= 5563

h

Basic function "

Limiter

"

Selection list

0 No response
1 Error
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

Subcodes

Lenze setting

Information

C02716/1

0: No response

Resp. to rotation limitation

C02716/2

3: Quick stop by trouble

Resp. to SW limit pos. excess

C02716/3

0: No response

Resp. to max. value excess

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02717 | LIM_dwControl

Data type: UNSIGNED_32

Index: 21858

d

= 5562

h

Control word of the basic function "

Limiter

" (LS_Limiter).

Display range

(min. value | unit | max. value)

0

4294967295

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02718 | LIM_dnState

Data type: INTEGER_32

Index: 21857

d

= 5561

h

Status of the basic function "

Limiter

" (LS_Limiter).

Display range

(min. value | unit | max. value)

0

1

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT

Parameter | Name:

C02719 | Limiter: Dig. signals

Data type: UNSIGNED_32

Index: 21856

d

= 5560

h

Display of the boolean input signals of the basic function "

Limiter

" (LS_Limiter).

Selection list

0 FALSE
1 TRUE

Subcodes

Information

C02719/1

LIM_bLimitSwitchPositive

C02719/2

LIM_bLimitSwitchNegative

C02719/3

LIM_bActivateLimitedSpeed1

;

Read access … Write access … CINH … PLC STOP … No transfer … COM … MOT