TAs for positioning tasks

TA "Multi-purpose positioning" | Program flow

386

Firmware 1.37 - 09/2006

L

Example
The following example illustrates the function of the variable branch based on a program

flow which contains, among other things, two actions of the "Variable branching" type.

[13.2] Example "Variable branch"

13.2.4.5

Sequencer inputs
In order to control conditional branches and the optional waiting function of some action

types during the program flow, 32 sequencer inputs of "BOOL" type.

r

The sequencer inputs 1 ... 16 can be linked with the signal sources of the application or

device interfaces in the dialog level Overview  L_Sequencer  Program inputs via

multiplexer parameters.

r

In case of the action types "positioning", "branching", "waiting" and "stand-by" it can be

defined for each action which of the sequencer inputs can be called during the program

sequence for the corresponding function.

Parameterise signal combinations

(C 237)

13.2.4.6

Sequencer outputs
Via a DWORD-to-BIT-converter, 32 sequencer outputs of type "BOOL" are available for

"switching" which can be set to FALSE or TRUE with the action type "switching".

r

These sequencer outputs can be connected with the inputs of the application or device

interfaces via multiplexer parameters.

Step 12

Step 13

Step 14

Step 15

Step 16

Step 17

Action number:

C03002

2

= 4

C04543/2 = 16

Action number:

C03003

3

= 20

C04559/3 = 12

1

n

2

1

n

2

W jump to step number [C04543/2]

W jump to step number [C04559/3]

Note!

The sequencer input 8 in the Lenze setting is linked with the digital input DI8.